Tips on how to Properly Remanufacture Your Own Lexmark Optra T-S-SE Toner Ink cartridges – Just 35 Simple steps
The Lexmark Opera To, Opera S, and Ie SE 3455 laser inkjet printer cartridges are all very similar but not interchangeable, with a few unique differences that will be pointed out later.
Since the remanufacturing procedure is the same, the next guidelines will be based on the Ie T yet address all cartridge types.
Here are your own Step-by-Step “How-to-Remanufacture Your Lexmark Optra T/S/SE 3455” Directions:
Let’s get straight to the idea, no beating around the rose bush during this lecture.
First, you will require the necessary Tools and Materials Required:
Tools & Materials Required:
Phillips #1 Electric screwdriver (tool)
oSmall Flat Edge Screwdriver (tool)
needle Nasal area Pliers (tool)
soft Soot Free Cloth (supply)
anhydrous Isopropyl Alcohol (supply)
cotton Swabs (supply)
vacuum (supply)
Here you will also be provided with the actual OEM (original equipment manufacturer) information:
Lexmark Optra T/S/SE 3455:
part Number: 12A0725 / 12A0825
OEM G Load: 620 grams
yield @ 5% coverage: twenty-three, 000 pages
one solution: twelve hundred dpi (dots per inch)
Lexmark Optra S1250 or S1255 / S1620 or S1625 / S1650 suggestions S1855 / S2420 suggestions S2450 /S2455:
apart Variety: 1382920 / 1382620
OEM Load: 250 grams
iPage Yield: 7, 500 websites
resolution: 1200 dpi (dots per inch)
apart Variety: 1382625 / 1382925 suggestions 12A0150
OEM Load: 600 grams
iPage Yield: teen, 600 pages
one solution: twelve hundred dpi (dots per inch)
Lexmark Optra SE 3455/SE 3455N:
part Number: 12A0725/12A0825
OEM Load: 620 Gary
iPage Yield: 23, 000 pages
resolution: 1200 dots per inch (dots per inch)
Lexmark Optra T610/T612/T612S/T614/T616:
apart Variety: 12A5740/12A5840
OEM Load: 270 grams
iPage Yield: 12, 000 pages
one solution: twelve hundred dpi (dots per inch)
Below are the 53 ways to know how to remanufacture your personal Lexmark Optra:
T/S/SE 3455:
o1382920
o1382620
o1382625
o1382925
o12A0725
o12A0825
o12A5740
o12A5840
o12A5745
o12A5845 series.
Table of Contents
Phase #1:
Place the cartridges on the work table with all the drums facing upward and the small drum gear in your direction. Using a small bladed electric screwdriver, pry off the developer spinning drive gear and set the item aside.
Step #2:
oRotate the cartridge to the suitable one so the toner hopper is facing you. Using a spring and coil hook or nasal needle pliers, gently remove the toner hopper tension springs from posts at each side.
Move #3:
to grasp the toner hopper with the left hand, along with the waste hopper side area with the right. Gently bend the adverse plate outward while slippage the toner hopper on the left to expose the proper guide write-up.
Step #4:
The carol cover may be taped in to facilitate handling. Using a modest flat-bladed screwdriver and needle-nose pliers, take off often the retaining clip on the left side with the drum shaft.
Step #5:
now you will need to hold the substantial gear end of the melody with your left hand and pull often the drum shaft out with the right. Remove the drum and put it aside; just be sure never to lose the washer around the small gear end. When lost, it may take some time to locate a new one, so be aware time is valuable.
Phase #6:
Next, remove a couple of screws holding the wiper blade using a #1 Phillips Screwdriver.
Step #7:
carefully slice the sealing mp3 on the topside of the waste material hopper covering the top of the wiper blade (instead, some cartridges use a foam seal at the rear of the wiper blade, if you do, delete this step if necessary). The PCR access entrance opens inward, and units on the horizontal lip in the wiper blade. Open the particular PCR door to remove the particular wiper blade and be very careful not to break the two tiny plastic alignment pins placement the wiper blade.
Phase #8:
umpty out the toner from the waste hopper and also inspect the recovery knife for nicks, tears, or perhaps wrinkles and replace it as required.
Step #9:
while having the waste hopper caries firmly with your right give and the wiper blade with your left. Open the PCR door with your left flash and install the wiper blade on the waste hopper and secure it with the Phillips screws.
Step #10:
Now, apply a small amount of padding powdered ingredients to the wiper blade, carol, and recovery blade. Put up the drum, washer, carol axle, and retaining show and set the waste hopper aside for now.
Note: If your OEM (original equipment manufacturer) drum comes
with the best way spring, it may need to be copied to the new drum.
Step #11:
Place the toner hopper on your work area (label up) with the developer roller experiencing you. Using your fingertips connected with both hands, gently pull off your doctor blade spring and set the item aside.
Step #12:
Using a small flat-bladed electric screwdriver and prying against the base with the contact plate may help contact and lift the bottom piece from the developer spinning.
Step #13:
rasp often the left end shaft with the developer roller and pick it up out to the left, doing your finest not to damage the Teflon washers or Mylar knives.
Step #14:
Remove the special Teflon washers from the designer roller and inspect these thoroughly for damage and wear. Replace the Teflon machines as a set.
Step #15:
Turn the toner hopper to the right so the load plug faces an individual. Using a small flat-bladed screwdriver, pry the slotted design encoder wheel off and make it aside.
Step #16:
Using the same screwdriver, pry out the toner fill, put it carefully, and do your best not to damage it. Clean your filter inside the plug together with either vacuum or squeezed air.
Step #17:
empty all the toner from your toner hopper and clean your hopper with a vacuum or perhaps compressed air. Be careful not to damage the foam rollers or Mylar blades.
Phase #18:
Using a natural cotton swab and isopropyl liquor, clean the developer roller, comes to an end, and seal at each ending of the foam roller.
Phase #19:
Clean the underside of the DR bar with a natural cotton swab and isopropyl liquor.
Step #20:
ocean beneath-the-ground contacts for the polyurethane foam roller shaft and the DOCTOR bar with a cotton clean and alcohol.
Step #21:
clean the developer spinning with dry soft tiny particles in the air-free cloth or pressurized air only. Clean the builder roller shaft with an organic cotton swab and alcohol.
Move #22:
install the Teflon washers on each end with the developer roller and trip the flat (keyed) stop of the roller into the situation on the right side with the toner hopper. Lower often the left end into the situation, careful not to deteriorate the Teflon washer with that side.
Step #23:
install the brass stop piece and contact area into position on the left stop developer roller shaft. For the Optra T and L’S 3455, rotate the man. uvres end piece downward before the lobe resting between the feet of the contact plate.
Move #24:
Re-install the MEDICAL PROFESSIONAL bar leaf spring together with the point of the “V” printed on the spring pointed closer.
Step #25:
Carefully dumps the correct amount of toner into your hopper and re-install often the fill plug.
Note: Often, the toner amount must be met to the correct encoder controls, key tab, and processor chip to ensure that the customer’s appliance does not reject the ink cartridge.
Step #26:
Re-install your aligner encoder wheel.
Step #27:
Place the waste hopper top down on your workplace with the opening facing you and the hopper tension Spgs out of the way. Turn the toner hopper label down in addition to inserting the left spinning guide into the slot. Cheaper the right side downwards, even pulling outward on the squander hopper side plate.
Move #28:
Re-insert the information posts into the proper cracks in the waste hopper edge plates and reattach often the hopper tension springs. Scrutinize thoroughly for correct toner hopper position and simplicity of movement.
Step #29:
Re-install the developer roller push gear. The cartridge has become ready to test.
Step #30a:
At last, align the particular encoder wheel with the about three slots in the down placement before packaging.
Step #30b:
Test the cartridge.
Great job, you have completed the method to remanufacture your own Lexmark Opera T/S/SE 3455 sequence LaserJet toner print carts.
Good luck, and complete each cartridge as if it were your last. This information is offered to you at no expense to be able to both educate and increase your knowledge in the technical location within the remanufacturing industry.
Inside description of, Joseph Ramo is known as The Internet Marketing Tyrant. He specializes in the exhaustible market involving studies in inkjet cartridges. Joseph is yet a respected Marketing Innovator who also seeks his innovative brain to construct proven ink formulations designed to leave major influences within this cartridge industry.
Now I’m a highly aggressive individual who is consistently seeking success. My assertiveness has brought me an amount of excellence within my market. I’ve been driven to the point connected with non-failure, and as a result, I advance daily while conquering wipe out. My intense innovations, which might be derived from my mind, have created and molded a defined professional such as myself. In addition , my expertise is far more than targeted at establishing a market with ink cartridges the size of the moment called the continent of Pangea. You can judge me as a Motivational Marketing Mechanic.
Read also: How To Remove Acrylic Paint